| Verified file | Measurement | Repair and reverification |
|---|---|---|
| Intermediate STEP `4afea50e` | The upper-right screw post overlaps the corner of the glass by 2.060795 mm³. The exact intersection spans X 113.9933…115.4500, Y −90.6000…−88.6504 and Z −0.0050…1.1950 mm. A second intersection check on the STL triangles using an independent geometry kernel gave 2.05663 mm³. | Moving the center to X 118.4, Y −95.0 mm and extending the edge to Y −100 mm has eliminated the intersection. The outer cylinder radius is 4.15 mm, and the clearance measured in revision `4fa1df23` is 1.1477 mm. The first delivered revision `b29e2fea` has the axis at X 118.55, Y −95.30 mm and 1.4805 mm at the nominal glass. |
| Intermediate STL files corresponding to `4afea50e` | In print orientation, the lowest vertices of the front enclosure STL are at Z +0.450 mm; those of the cover are at +0.147 mm. | In `4fa1df23`, the lowest measured Z across all 11 STL files is 0. The exporter recentered the final triangles. |
| Intermediate STEP `4afea50e` | One corner of the 13 × 7 mm USB gauge was obstructed over 0.64625 mm². A second intersection check on the STL measured a volume of 1.41526 mm³ at X −7.495…−5.005, Y 72.950…73.500, Z −1.825…−0.650 mm. | In `4fa1df23`, the opening is clear through its full depth. The minimum Euclidean distance between the gauge and the projected enclosure outline is 0.518 mm. |
| Intermediate STEP `4afea50e` | During the designer's verification, the common face with the back, the frame, and the two cross members produced positive volumes between the rigid components. | The independent check of `4fa1df23` tested all 55 pairs of printed parts and found no positive intersection volumes. |
| Intermediate STEP `4fa1df23` | The maximum-size battery-pack gauge touched the guard posts after moving 0.50 mm in either X direction. | In revision `b29e2fea`, the pillar displacements outward and subsequent contact with the rails leave a clearance of 0.7500 mm. Measurement on the delivered triangles includes the first intersection within the range 0.750000–0.750092 mm on both sides. |
| First delivered assembly `b29e2fea` | Two sidewalls around the display glass have been adjusted to facilitate the insertion of the screen connected to the PCB. | Along the full 20 mm insertion travel, the maximum glass envelope includes flex displacement and has zero intersection volume. Expanding it on all sides by a further 0.5000 mm reaches the first obstruction. STL check |
| USB revision `9b77992a` | The reverse search identified 41 lines of sight to the PCB along the sides of the recess. | The narrowed flanks of revision `0ecf7606` intersect all 41 rays at nine positions. [Regression on B-rep](usb/historical-rays-solid-sections.json) |
| USB revision `0ecf7606`, earlier mask acceptance criteria | In the model, a PET mask with a radial offset of 0.0311 mm and a contour enlarged by 0.020 mm passed the old checks but left a line of sight to the PCB at the steel corner when the adhesive was treated as transparent. | For acceptance, each assembly must have at least 0.005 mm of projected coverage after measurement uncertainty, in every direction permitted by the recess. The witness sample fails at −0.032088 mm, while the nominal profile passes at +0.008211 mm. [Measured geometry and the five tests](usb/directional-receiving.json) |

Intermediate measurements preserved · Full verification of the delivered CAD revision

For the USB revision, separate port measurements document the original cutout and the two successive series of opaque shields. USB geometry comparison · Results by revision